- Home
- Search for Research Summaries, Reviews, and Reports
EHC Component
- EPC Project
Topic Title
Full Report
- Research Review Dec. 29, 2011
Related Products for this Topic
- Research Protocol Jul. 1, 2010
- Disposition of Comments Report May 2, 2012
- Executive Summary Dec. 29, 2011
Related Links for this Topic
- CME Activity: Adjunctive Devices for Patients With Acute Coronary Syndromes Undergoing Percutaneous Coronary Intervention
- Slide Talk: Adjunctive Devices for Patients With Acute Coronary Syndromes Undergoing Percutaneous Coronary Intervention
-
Sobieraj DM, White CM, Kluger J, et al. Systematic review: comparative effectiveness of adjunctive devices in patients with ST-segment elevation myocardial infarction undergoing percutaneous coronary intervention of native vessels. BMC Cardiovasc Disord 2011 Dec 20;11(1):74 [Epub ahead of print]. PMID: 22185559.
Original Nomination
Clinician Summary – May 16, 2012
Adjunctive Devices in PCI To Remove Thrombi or Protect Against Distal Embolization in Patients With ACS
Formats
- View PDF (PDF) 334 kB
- Help with Viewers, Players, and Plug-ins
Table of Contents
- Focus of Research for Clinicians
- Background Information
- Conclusion
- Clinical Bottom Line
- Glossary of Terms
- Gaps in Knowledge
- Figure 1. Explanation of Thrombectomy and Embolic Protection Devices Studied
- Ordering Information
- Source
Focus of Research for Clinicians
A systematic review of 175 clinical studies published between January 1996 and March 2011 sought to determine the comparative effectiveness, benefits, and adverse effects of adjunctive devices to remove thrombi or protect against embolization in patients with acute coronary syndromes (ACS) undergoing percutaneous coronary intervention (PCI) of native vessels. This summary is provided to assist in decisionmaking along with consideration of a patient’s values and preferences. Reviews of evidence should not be construed to represent clinical recommendations or guidelines. The full report is available at www.effectivehealthcare.ahrq.gov/thrombusacs.cfm.
Background Information
Outcomes of PCI have improved with the use of coronary stents and adjunctive pharmacologic agents. However, distal embolization caused by the dislodgement of atherothrombotic material from coronary lesions during PCI can lead to the “no-reflow phenomenon,” which results in significantly higher morbidity and mortality for patients with ACS. Several adjunctive devices have been developed to remove thrombi and to protect against distal embolization during PCI (Figure 1). They are classified into catheter aspiration thrombectomy, mechanical thrombectomy, and embolic protection devices. The comparative effectiveness and the risk differences between these devices in patients with ACS undergoing PCI for native coronary arteries are not well established.
Conclusion
Catheter aspiration thrombectomy reduces the occurrence of major adverse cardiovascular events, distal embolization, and no reflow and improves ST-segment elevation resolution and coronary flow when used as an adjunctive therapy for patients with ST-segment elevation myocardial infarction (STEMI) who are undergoing primary PCI. Evidence does not support benefits from mechanical thrombectomy or embolic protection devices, which appear to prolong procedure time. Current evidence is too limited to permit conclusions about the comparative benefits and harms of these devices with respect to final health outcomes and adverse events.
Clinical Bottom Line
Devices to remove thrombi or protect against distal embolization in patients with ACS who were undergoing PCI of native vessels were compared with standard PCI.
PATIENTS WITH STEMI
Catheter Aspiration
Final Health Outcomes
- Significantly decreased the risk of MACE by 27%; 33 people with STEMI need to be treated with a catheter aspiration device to prevent one MACE (NNT=33).
.png)
- No significant impact on death, MI, or target lesion revascularization.
.png)
Intermediate Outcomes
- Significantly reduced distal embolization by 44% (NNT=12).
.png)
- Significantly reduced no reflow by 48% (NNT=15).
.png)
- Significantly increased the resolution of ST-segment elevation by 51% (NNT=5), achievement of MBG-3 by 61% (NNT=5), and TIMI-3 flow by 8% (NNT=17).
.png)
- Did not significantly impact ejection fraction.
.png)
- Reduced the risk for coronary dissection by 70% (NNT=50).
.png)
- Does not prolong procedure time.
.png)
Mechanical Thrombectomy
- Evidence was insufficient to determine the effects on final health outcomes (mortality, MACE, reinfarction, stroke, or target lesion revascularization).
.png)
- Had no significant effects on these intermediate health outcomes:
- ST-segment resolution
.png)
- Ejection fraction
.png)
- Achievement of MBG-3
.png)
- TIMI-3 flow
.png)
- Risk of distal embolization
.png)
- ST-segment resolution
- Average procedure times were prolonged by approximately 9–16 minutes.
.png)
Embolic Protection Devices
- Evidence was insufficient to determine the effects on some final health outcomes including mortality, reinfarction, and stroke for most embolic protection devices.
.png)
- Embolic protection devices did not significantly affect MACE.
.png)
- Overall, embolic protection devices did not significantly affect these intermediate outcomes:
- Ejection fraction
.png)
- Risk of distal embolization
.png)
- Achievement of ST-segment resolution
.png)
- Ejection fraction
- Distal balloon embolic protection devices significantly increased achievement of MBG-3 by 39% (NNT=7)
and TIMI-3 flow by 11% (NNT=13)
. - Proximal balloon devices increased the median procedure time by approximately 14 minutes.
.png)
- Distal balloon embolic protection devices increased average procedure times by approximately 23 minutes.
.png)
- Distal filter embolic protection devices increased target lesion revascularization by 61% (NNH=25).
.png)
PATIENTS WITH MIXED ACS (STEMI, NSTEMI, OR UA)
Catheter Aspiration
- Achievement of MBG-3 was almost 4.5-fold more likely with the use of a catheter aspiration device than without it (NNT=3).
.png)
- Evidence on catheter aspiration devices was insufficient with respect to final health outcomes and additional intermediate outcomes.
.png)
- No available studies evaluated adverse events for this device in this population.
Mechanical Thrombectomy
- Mechanical thrombectomy devices significantly improved ST-segment resolution by 58% (NNT=3).
.png)
- Evidence supporting mechanical thrombectomy devices was insufficient with respect to final health outcomes and additional intermediate outcomes.
- No available studies evaluated adverse events for this device in this population.
Embolic Protection Devices
- Distal balloon embolic protection devices significantly increased the resolution of ST-segment elevation by 58% (NNT=3)
and the achievement of MBG-3 by 3-fold (NNT=2)
, and significantly reduced the risk of no reflow by 64% (NNT=2). .png)
- Procedure times were prolonged by a mean of 7 minutes.
.png)
ACS = acute coronary syndrome; MACE = major adverse cardiovascular events (including reinfarction, target lesion revascularization, and stroke); MBG-3 = myocardial blush grade 3; MI = myocardial infarction; NNH = number needed to harm; NNT = number needed to treat; NSTEMI = non-ST segment elevation myocardial infarction; STEMI = ST-segment elevation myocardial infarction; TIMI-3 = thrombolysis in myocardial infarction flow grade 3; UA = unstable angina
Strength of Evidence Scale
High: ![]()
There are consistent results from good-quality studies. Further research is very unlikely to change the conclusions.
Moderate: ![]()
Findings are supported, but further research could change the conclusions.
Low: ![]()
There are very few studies, or existing studies are flawed.
Insufficient: 
Research is either unavailable or does not permit estimation of a treatment effect.
Glossary of Terms
Myocardial blush grade (MBG): An angiographic method of grading myocardial tissue perfusion ranging from grade 0 to grade 3.
Thrombolysis in myocardial infarction (TIMI) blood flow: An angiographic method of grading blood flow in an epicardial coronary artery with a range from grade 0 to grade 3.
Gaps in Knowledge
- Direct comparative randomized controlled trials are needed that compare one thrombectomy or embolic protection device with another and evaluate final health outcomes.
- Studies examining final health outcomes and using longer followup data are needed to fully determine the comparative effectiveness, benefits, and harms of adjunctive thrombectomy and embolic protection devices in patients with ACS who are undergoing PCI.
Figure 1. Explanation of Thrombectomy and Embolic Protection Devices Studied

Figure 1. Explanation of Thrombectomy and Embolic Protection Devices Studied. Numerous adjunctive devices have been developed to help improve clinical outcomes by removing thrombi and to protect against distal embolization during PCI. These devices utilize different technologies and are broadly classified as catheter aspiration, mechanical thrombectomy, or embolic protection devices (i.e., distal or proximal embolic balloon or distal filter protection devices).
(A) Catheter aspiration thrombectomy uses a catheter that is advanced over a guidewire to the thrombus where manual syringe suction is used to aspirate the debris.
(B) Mechanical thrombectomy devices apply energy through saline jets or a rotating catheter head to facilitate breakup of the thrombus before its active aspiration.
(C) Proximal embolic protection devices employ an occlusion balloon advanced over a guidewire proximal to the thrombus to trap and aspirate thrombotic debris released during angioplasty and stenting procedures.
(D and E) Distal embolic protection devices are similar to proximal devices, except they employ an occlusion balloon (D) or filter (E) advanced over a guidewire distal to the thrombus to trap and aspirate (balloon devices) or capture and retrieve (filter devices) thrombotic debris released during angioplasty and stenting procedures.
Ordering Information
For electronic copies of this clinician research summary and the full systematic review, visit www.effectivehealthcare.ahrq.gov/thrombusacs.cfm. To order free print copies, call the AHRQ Publications Clearinghouse at 800-358-9295.
Source
The information in this summary is based on Adjunctive Devices for Patients With Acute Coronary Syndrome Undergoing Percutaneous Coronary Intervention, Comparative Effectiveness Review No. 42, prepared by the University of Connecticut/Hartford Hospital Evidence-based Practice Center under Contract No. 290-2007-10067-I for the Agency for Healthcare Research and Quality (AHRQ), December 2011. Available at www.effectivehealthcare.ahrq.gov/thrombusacs.cfm.
This summary was prepared by the John M. Eisenberg Center for Clinical Decisions and Communications Science at Baylor College of Medicine, Houston, TX.
It was written by Andrea Humphries, Thomas Workman, Hani Jneid, and Michael Fordis.
Return to Top of Page

E-mail Updates