Skip Navigation
Department of Health and Human Services www.hhs.gov
  • Home
  • Search for Research Summaries, Reviews, and Reports
 
 

EHC Component

  • DEcIDE Project

Topic Title

  • Real World Effectiveness of Implantable Cardioverter Defibrillators (ICDs) in Medicare Patients
Save this page in Facebook.com  Save this page in Myspace.com  Save this page in Twitter.com  Save this page on your Google Home Page  Save this page in Windows Live
Save this page in Yahoo  Save this page in Ask.com  Stumble this page.  Save this page in del.ico.us  Digg this page. 

E-mail E-mail   Print Print

Add to My Collections



Abstract - Draft – Apr. 14, 2010

Real World Effectiveness of Implantable Cardioverter Defibrillators (ICDs) in Medicare Patients

Topic Abstract

Background: Although ICDs provide meaningful prolongation of life for patients in clinical trials at high risk for sudden cardiac death (SCD), data are lacking on the effectiveness of ICDs in patients who receive Medicare benefits.

Research Objectives:
Aim 1: To demonstrate differences in the incidence rate of death and cardiovascular hospitalizations between trial patients and Medicare patients who are undergoing ICD implantation.
Aim 2: To explore whether the incidence of death and cardiovascular hospitalizations after ICD implantation differ by gender, age category, and comorbidities.
Aim 3: To identify subgroups of patients undergoing ICD implantation for whom: 1) ICDs are not effective (expected survival < 18 months); and 2) ICDs are not cost-effective (expected survival < 5 years).
Aim 4: To estimate the incidence of various potential short and long-term adverse events following ICD implantation.
Aim 5: a) To directly compare the effectiveness of ICD versus medical management and b) to assess the impact of unmeasured confounding by indication or severity in a well-designed comparative effectiveness study.
Study design: Retrospective cohort study

Methods:
Data Source: 1) the CMS ICD Registry, 2) the Heart failure/Myocardial infarction (HF/MI) registry and 3) Medicare eligibility, Part A, B and D data.

Participants, setting, and expected sample size: The study utilizes the following: a) >400,000 patients in the CMS ICD registry, or b) >50,000 similar patients in the Outcome HF/MI registry and c) patients from the entire Medicare data with heart failure or myocardial infarction who meet a claims-based definition for low-ejection fraction and other National Coverage Decision (NCD) criteria for ICDs but did not receive ICDs. We will further require that these patients: 1) be ≥65 years at the time of receiving ICD or a matched random date; and 2) are eligible for Medicare ≥12 months prior to the date of cohort entry.

Exposure(s): ICDs

Outcomes: The following are study outcomes: all-cause death, hospitalization for heart failure and other cardiovascular events (i.e., myocardial infarction; stroke). To define these events, we will use previously validated definitions with very high specificity.

Statistical methods: Survival analyses and logistic regression will be used to describe and predict outcomes. We will use Cox regression to compare ICD and non-ICD after adjusting for confounders using multivariate adjustment or high-dimensional propensity score (hd-PS).

Comparator groups: No ICDs with medical treatment

Expected Outputs: Scientific reports

Expected Date of Project Completion: 9/30/2011